PRIME IS YOUR ONE STOP SHOP

FREEZE PROTECTION, GLYCOL & COMMISSIONING SUPPORT

FREEZE PROTECTION, GLYCOL & COMMISSIONING SUPPORT

FREEZE PROTECTION, GLYCOL & COMMISSIONING SUPPORT

Engineering-led precision for the systems and tests that determine whether a project is ready to turn over.

  • Service List Icon

    Freeze Protection Circulation

  • Service List Icon

    Glycol Injection Services

  • Service List Icon

    Glycol Storage Services

  • Service List Icon

    System Hydrostatic Testing

  • Service List Icon

    False Load Heating

  • Service List Icon

    Freeze Protection Circulation

  • Service List Icon

    Glycol Injection Services

  • Service List Icon

    Glycol Storage Services

  • Service List Icon

    System Hydrostatic Testing

  • Service List Icon

    False Load Heating

  • Service List Icon

    Freeze Protection Circulation

  • Service List Icon

    Glycol Injection Services

  • Service List Icon

    Glycol Storage Services

  • Service List Icon

    System Hydrostatic Testing

  • Service List Icon

    False Load Heating

Case Study Image

COVERAGE

Freeze Protection to Commissioning

STANDARD

Verified Under Real Operating Load

Case Study Image

COVERAGE

Freeze Protection to Commissioning

STANDARD

Verified Under Real Operating Load

Case Study Image

COVERAGE

Freeze Protection to Commissioning

STANDARD

Verified Under Real Operating Load

EVERY TEST BEFORE TURNOVER. HANDLED.

From freeze protection through final heat-load simulation, Prime treats every commissioning test as one coordinated scope, not a series of handoffs.

FREEZE PROTECTION CIRCULATION

Continuous water movement through exposed or vulnerable piping during low-temperature periods prevents freeze-related damage.

Circulation During Low Temps

Flow & Temperature Monitoring

Equipment Performance Tracking

Freeze-Damage Prevention

FREEZE PROTECTION CIRCULATION

Continuous water movement through exposed or vulnerable piping during low-temperature periods prevents freeze-related damage.

Circulation During Low Temps

Flow & Temperature Monitoring

Equipment Performance Tracking

Freeze-Damage Prevention

GLYCOL INJECTION SERVICES

Glycol is delivered and injected using a stainless-impeller centrifugal pump, with filtration at every vulnerable point to reach target concentration.

Lined or Stainless Bobtail Transport

Stainless-Impeller Centrifugal Pump

Filtration at Every Vulnerable Point

Target Concentration Reached

GLYCOL INJECTION SERVICES

Glycol is delivered and injected using a stainless-impeller centrifugal pump, with filtration at every vulnerable point to reach target concentration.

Lined or Stainless Bobtail Transport

Stainless-Impeller Centrifugal Pump

Filtration at Every Vulnerable Point

Target Concentration Reached

GLYCOL STORAGE SERVICES

Clean, compliant, secure temporary storage in lined or stainless tanks, configured to project constraints and cleanliness specifications.

Lined or Stainless Tank Storage

Configured to Project Constraints

Cleanliness Specification Compliance

Full Volume Documentation

GLYCOL STORAGE SERVICES

Clean, compliant, secure temporary storage in lined or stainless tanks, configured to project constraints and cleanliness specifications.

Lined or Stainless Tank Storage

Configured to Project Constraints

Cleanliness Specification Compliance

Full Volume Documentation

SYSTEM HYDROSTATIC TESTING

Controlled hydrostatic pressure testing verifies piping, joints, valves, and components meet specified test pressure before commissioning.

High-Pressure Centrifugal Pump Truck

Piping, Joint & Valve Verification

Specified Test Pressure Confirmation

Full Documentation of Results

SYSTEM HYDROSTATIC TESTING

Controlled hydrostatic pressure testing verifies piping, joints, valves, and components meet specified test pressure before commissioning.

High-Pressure Centrifugal Pump Truck

Piping, Joint & Valve Verification

Specified Test Pressure Confirmation

Full Documentation of Results

FALSE-LOAD HEATING

A direct-fire helical coil boiler system creates a false heat load, simulating real operating conditions so pumps, coils, and heat exchangers can be tested before final turnover.

Direct-Fire Helical Coil Boiler

False-Load Simulation

Pumps, Coils & Heat Exchangers Tested

Verified Before Final Turnover

FALSE-LOAD HEATING

A direct-fire helical coil boiler system creates a false heat load, simulating real operating conditions so pumps, coils, and heat exchangers can be tested before final turnover.

Direct-Fire Helical Coil Boiler

False-Load Simulation

Pumps, Coils & Heat Exchangers Tested

Verified Before Final Turnover

OUR COMMITTMENT

LESS WATER

Reducing water consumption guides how we approach every project. Our patent-pending closed-loop RO flushing process is engineered to cut water use during commissioning.

Button Arrow

Learn More

Color 1← →

OUR COMMITTMENT

LESS WATER

Reducing water consumption guides how we approach every project. Our patent-pending closed-loop RO flushing process is engineered to cut water use during commissioning.

Button Arrow

Learn More

Color 1← →

OUR COMMITTMENT

LESS WATER

Reducing water consumption guides how we approach every project. Our patent-pending closed-loop RO flushing process is engineered to cut water use during commissioning.

Button Arrow

Learn More

Color 1← →